Sulfurchrome GC for Sulfur Content Determination

Download Product Documentation

Specifications

SPEC VALUE
Span Drift +/- 2% F.S.
Accuracy +/- 2% F.S.
Repeatability +/- 2% F.S.
Sensitivity 1% F.S.
Linearity +/- 2% F.S.
Response time 4 to 15 minutes, application dependent
Ambient temperature 0°C to 50°C (32° F to 122°F)
Dimensions 711 mm H x 1016 mm W x 406 mm D (28” H x 40” W x 16” D)
Weight 57 kg (125 lbs)
Power and consumption 100-240 VAC, 50/60 Hz
600 watts
Sample flow 100 cc/min, 1 barg (0.21 SCFH, 15 psig)
Air requirements 37.7 L/min, 5.3 barg to 8 barg (80 scfh, 80 - 120 psig)
Gas requirements Helium: 20 cc/min, 5.3 to 6.7 barg (0.042 scfh, 80-100 psig)
Hydrogen: 80 cc/min, 4 to 5.3 barg (0.17 scfh, 60-80 psig)
Digital Outputs Modbus RS232, Modbus RS485
Digital Inputs 6 dry contact, 2 wet
Analog Outputs 4 x 4-20 mA, user scalable, user selectable loop or self powered
Relays 4 x SPDT relays, 8 amp @250 VAC
Approval and Certifications CSA General Pupose
CSA, Class 1 Division 2, Group B,C,D (with air purge)

Features and Benefits

Do you need to monitor odorant levels in hydrocarbons? That requires high-sensitivity detection and measurement of the individual sulfur components. Some natural gas pipeline custody-transfer applications also require detailed reporting of sulfur and its various components. Galvanic’s SulfurChrome online gas chromatograph makes it easy, enabling simultaneous, real-time measurement of all sulfur compounds down to the 5 ppb level.

Speciated Sulfur Measurement For Accurate Process Analysis

Due to the reactive nature of sulfur compounds, calibration standards containing multiple sulfur components are normally unstable. This is particularly true at the lower ppm levels. However, this problem is eliminated with the SulfurChrome analyzer. Its equal and selective response allows the standard to be made up with a single least reactive sulfur component in an inert background gas such as nitrogen. This standard is then available for on-line auto calibration and reference check functions. The system equally easy to operate and maintain, with user-configurable alarms, range, streams, and valve times. Inert silco-steel capillary columns are used for sulfur separation, providing long life and trouble-free operation. Sulfur separations can be made isothermally out to C4 mercaptans in fewer than 10 minutes. Standard outputs are 4-20 ma. Modbus communication is available.